LSC detectors: research plan

A lower number in the "Priority" column runs sooner.

Priority

Id Question Priority Waits for State
SW2 Which change to the switching detector raises the share of moved MW found at an acceptable alarm rate? Not set Nothing Iterations SW2-5 to SW2-9 are done (experiments 68, 61, 60, 55, and 62); further iterations are proposals; experiment 181 found that a block detector finds 0 of 17 unlabelled block days at RO-NC's alarm budget, and the candidate label table awaits NGED review
309 Can the gap between a no-lag forecast and a forecast with lags tell NGED which one to use, without knowing the truth? High (maintainer approved 2026-10-23) Nothing Planned
186 Are D8's multi-day drops an embedded gas peaker running (spark spread, triads, flat blocks)? High (NGED answer relayed 2026-10-22) Nothing Planned

Experiment 00116 (differentiable physics, NRA) also bears on this theme. It fits flows on the interconnection edges between Primary substations and scores them on injected transfers; see the Network research plan.

Planned experiments

Experiment Hypothesis Relevance

Proposals in detail

SW2: switching-event detection

The SW2 line improves the switching-event detector first, scored by event-level F1 against a labelled set of visible events, and leaves the use of the detector until the detector works. The detector serves two purposes later. The first is a lower forecast error, if switching periods act as unexplained noise for the XGBoost model and corrupt its lagged power inputs. The second, and the more important to NGED, is a forecast under the normal running arrangement (NRA), into which NGED can add its own switching. The switching events roadmap page proposes building that forecast by excluding switching periods from the training target. An event table for NGED is a third purpose, at lower priority. The production detector has to run on power alone, because the switching logs exist only for the trial area, so the logs are used here for evaluation only.

The line reopens a question that experiment 00038 closed, because experiment 00038 tested a different use of the detector. Experiment 00038 masked detected switching from the history of the error correction that runs after the XGBoost model, and the mask made the forecast worse. No experiment has yet masked switching from an XGBoost training target or from a lagged input. Experiment 00037 confirmed 37 of 612 logged closures of 2 hours to 60 days as visible in its own residual, and scored its detectors on the 18 of them in the validation months. That reference set is small, about 6 of the 37 are expected by chance, and the label was built from the residual the detectors use, so a detector that shares the residual's blind spots is flattered by the label. The line therefore starts by building a reference set independent of the detectors.

The full labeller design is in the private file data/ml-experiments/briefs/sw2_labeller_design.md.

SW2-4 to SW2-9: detector iterations

Each iteration tests one change to the detector against the experiment 43 scoreboard, tuned on injections and odd months, scored on even months, with recall weighted by the MW moved as the headline from SW2-7 onwards. The order below is a proposal, by expected gain per hour of work, for the plan of each iteration to confirm:

  • SW2-5 (done, experiment 68): three rounds of refitting the lagless XGBoost model without the detected intervals changed the share of the moved MW found by +0.011 and the forecast error by -0.175%, and a random mask did as well.
  • SW2-6 (done, experiment 61): pairing the onset and return steps into one alarm score finds less than D0M at the same alarm rate, but taking the end of D0M's interval from the strongest opposite step in the next 14 days finds 0.19 more of the moved MW.
  • SW2-7 (done, experiment 60): a step statistic that weights each half-hour by the expected power found the same transfers as the constant step on five injection shapes, so the step's shape does not limit the 24-hour detector. About a third of the transfers with a donor step of 6 noise units or more have the right onset and the wrong end, which SW2-6 (paired-step intervals) addresses.
  • SW2-8 (done, experiment 55): a single-series detector first, with neighbour balance as a sense check, not a gate. Every single-series alarm stands. A metered neighbour's opposite step raises the alarm's confidence and names the receiver, a same-sign step on the neighbours vetoes the alarm as a common-mode weather or calendar miss, and an alarm with no metered neighbour keeps its single-series confidence. Experiment 00043 found the neighbour-balance detector D1, which uses the neighbour test as a gate, finding almost none of the injected transfers without a metered receiver. The sum of the neighbourhood's residuals and a subset-sum over neighbours for a split feed the confidence score.
  • SW2-9 (done, experiment 62): whitening, experiment 00037's proposed F4, an autoregressive model of order 1 per series and hour of day fitted to the residual. The filtered detector found less of the moved MW (-0.097 at 24 hours), because the filter shrinks a day-long step faster than the noise of the 24-hour step.